Biblioteca Virtual

Desinfección de aguas utilizando radiación ultravioleta (UV): estudio de la cinética de fotoinactivación y reparación a oscuras

Mostrar el registro sencillo del ítem

dc.contributor.advisor Martín, Carlos Alberto
dc.contributor.author Trombert, Alejandro Raúl
dc.contributor.other Capparelli, Alberto
dc.contributor.other Claus, Juan
dc.contributor.other Litter, Marta
dc.date.accessioned 2009-04-21
dc.date.issued 2008-02-29
dc.identifier.uri http://hdl.handle.net/11185/110
dc.description Fil: Trombert, Alejandro Raúl. Universidad Nacional del Litoral. Facultad de Ingeniería Química; Argentina.
dc.description.abstract Los procesos tradicionales para la desinfección de aguas emplean derivados del cloro y tienen un uso cada vez más restringido. El empleo de radiación ultravioleta (UV) presenta potencialidades pero su aplicación enfrenta problemas debido a la falta de capacidad residual para prevenir recontaminaciones. El efecto germicida de la radiación UV se basa en el daño sobre el ADN pero, producto de la evolución, los microorganismos han desarrollado mecanismos como la foto-reparación y la reparación a oscuras, fenómenos que deben incluirse en las expresiones cinéticas necesarias para diseñar equipos eficientes. Para modelar la cinética completa del proceso se diseñó, construyó y modeló un fotorreactor anular batch escala laboratorio iluminado con una fuente UV germicida y se empleó Escherichia coli como modelo. Además, se seleccionaron y adaptaron diferentes técnicas de Biología Molecular (PCR) para obtener evidencias a nivel molecular de los fenómenos ocurrentes. Se obtuvo una expresión que vincula la velocidad de reacción con la concentración microbiana, el nivel de irradiación y parámetros cinéticos del sistema. La condición de mezcla perfecta fue verificada empleando estudios de tiempos de residencia con trazadores y para el campo radiante se empleó un modelo de emisión volumétrica. El análisis comparativo de los resultados experimentales con las predicciones del modelo se desarrolló combinando la verificación de hipótesis “cualitativas” -estudios de ADN- con análisis numérico iterativo para obtener los parámetros cinéticos, empleando un estimador no-lineal tipo Levenberg-Marquardt, logrando disponer finalmente de un modelo cinético completo, verificado cuali-cuantitativamente, y que representa detalladamente los fenómenos que intervienen en el proceso. es
dc.description.abstract Conventional processes for water disinfection use chlorine and they have an increasingly restricted use. Ultraviolet radiation (UV) presents potentialities but its application still faces problems due to the lack of residual capacity to prevent re-contaminations. The germicidal effect of UV is based on the damage on the DNA but, as a consequence of the evolution, microorganisms have developed mechanisms such as photo-repair and dark repair which have to be included in the kinetic expressions needed for the design of efficient equipments. In order to model the complete kinetics of the process we design, construct and model a batch annular photoreactor -scale laboratory- illuminated with a germicidal UV source and we used Escherichia coli as a model. In addition, we select and adapt different techniques of Molecular Biology (PCR) in order to obtain evidences, at molecular level, of the phenomena that occur. We obtained an expression which relates the reaction rate with the concentration of microorganisms, the irradiation level and kinetic parameters of the system. The condition of perfect mixing was carefully verified employing residence time studies with tracers and for the radiant field we employed a model of volumetric emission for the source (lamp). The comparative analysis of experimental results with model’s predictions was developed combining the verification of “qualitative” hypothesis with quantitative iterative numerical analysis in order to obtain the kinetic parameters, employing a Levenberg-Marquardt non linear estimator, achieving finally a complete kinetic model which represents the phenomena that take part in the overall process. en
dc.description.sponsorship Consejo Nacional de Investigaciones Científicas y Técnicas es
dc.description.sponsorship Universidad Nacional del Litoral
dc.format application/pdf
dc.format.mimetype application/pdf
dc.language spa
dc.language.iso spa es
dc.rights info:eu-repo/semantics/closedAccess
dc.rights.uri Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.subject Disinfection en
dc.subject UV radiation en
dc.subject Dark repair en
dc.subject Kinetics en
dc.subject PCR en
dc.subject Desinfección es
dc.subject Radiación UV es
dc.subject Reparación a oscuras es
dc.subject Cinética es
dc.subject PCR es
dc.title Desinfección de aguas utilizando radiación ultravioleta (UV): estudio de la cinética de fotoinactivación y reparación a oscuras es
dc.title.alternative Water disinfection using ultraviolet radiation (UV): study of photo-inactivation and dark repair kinetics en
dc.type info:eu-repo/semantics/doctoralThesis
dc.type info:ar-repo/semantics/tesis doctoral
dc.type info:eu-repo/semantics/acceptedVersion
dc.type Thesis es
dc.contributor.coadvisor Irazoqui, Horacio Antonio
unl.degree.type doctorado
unl.degree.name Doctorado en Tecnología Química
unl.degree.grantor Facultad de Ingeniería Química
unl.formato application/pdf
unl.versionformato 1a
unl.tipoformato PDF/A-1a
dc.date.embargosinedie si


Ficheros en el ítem

Este ítem aparece en

Mostrar el registro sencillo del ítem

Buscar en la biblioteca